Sr. No. | Field and parameter | Major Equipments | Model/Type | Range | Overall Measurement Accuracy |
1 | DC/AC Volt DC/AC Current Resistance | Digital Multimeter HP | 34401A | DC V: 1000 V AC V:750 V DC A: 3 A AC A: 3A R:100 MΩ | ± 0.0050 % rdg |
2 | Frequency(Source) | Leveled Sine Wave Generator Tektronix | SG503 | 250 MHz | ± 0.7 % of LSD |
3 | Frequency (measure) | Frequency Counter HP | 53181A | Freq: 225 MHz Time: 4.4S to 10S | 0.0025 ppm |
4 | Inductance Capacitance Resistance | LCR Meter HP | E4925A | 10 H 1μ F 1 MΩ @ 1kHz | ± 0.25 % |
5 | AC/DC High Voltage | HV Probe Motwane | HV-40 | 40 k V peak | 1.5 % of F.S. |
6 | AC/DC High Current | Current Shunt, PEMI | 030267 | 500 A
| ± 0.5 % |
7 | Temperature | PT 100 Sensor YENKAY | CLASS B
| -40 to 250º C | ±0.5º C |
8 | Volts/Div Time/Div Bandwidth | Digital Storage Oscilloscope Philips | OS3060 | 60 MHz | ± 3 % |
9 | Temperature | PT 100 Sensor Hi-Tech Trans and Devices | CLASS B | -40 to 250º C | ±0.5º C |
10 | DC milli Volt DC milli Amp Temperature(PT 100 simulator) | Universal Calibrator
| PC-UC-45M | 200 mV 20 mA -50 to 600º C | ± 0.1 % ± 0.1 % ± 0.05 Ω |
11 | DC/AC Volt DC/AC Current Resistance | Digital Multimeter Fluke | 45 | DC V: 1000 V AC V: 750 V DC A: 10 A AC A: 10A R: 100 MΩ | ± 0.025 % |
12 | AC/DC Current | Current Shunt HP | 34330 |
| ± 0.3 % |
13 | AC/DC Voltage, AC / DC Current, Frequency | Multi Function Calibrator | ZS- MFC | DC V: 1000 V AC V:750 V DC A: 10A AC A: 10A | ± 0.1 % |
By maintaining the hygienic conditions, using an excellent grade of raw materials, most upgraded machines and contemporary techniques, we are able to maintain the quality of products. We manufacture this range of testing and measuring equipments in compliance with international quality standards. Thus, due to our quality delivery of product range.